FEATURES |
2 Opto-Isolated inputs |
12 ISO-Drive NMEA 0183 outputs |
Ethernet Port |
Flexible operating modes |
Automatic Baud Rate matching on inputs |
Alarm output options |
Web based configuration tool |
Diagnostic LEDs |
Advanced Data Filtering and Routing |
2 virtual Autoswitch modules |
Data statistics and load indication via web tool |
Designed for 12 / 24 Volt supply |
Future proofing with easily upgradable firmware |
2-part pluggable connector system |
Stainless Steel Housing with DIN rail mount option |
Type Approved |
BENEFITS |
Flexible configuration options to buffer autoswitch or combine NMEA data |
ISO-Drive separates the Listener from the Talker to protect both the PRO-BUF and each connected device. |
Fast bi-directional data connection to a monitor and control software application |
PRO-BUF can be configured using any web browser on any Operating system |
Works out-of-the-box without configuration for basic installations, or can be easily user configured as required |
Relay output is compatible with on-board alarm systems and NMEA Alarm sentence can be displayed and actioned on an MFD |
Easy to access via network, doesn’t require the device to be moved or have a serial connection to the PC. |
Quick visual check gives the user confidence that each input and output is passing data |
Features can be utilised to fine tune data, avoiding data overloads on the outputs and connected listeners |
Allows automatic data priority selection between two devices of the same type of data (e.g. GPS) |
Shows the NMEA 0183 on each I/O Port, and how frequently it arrives, great for low level diagnostics |
Allows use on large vessel 24V DC power supplies systems |
Additional features in future firmware revisions are accessed using a simple update process via Actisense Toolkit over Ethernet |
Fast installations and supports both screw and screwless terminal types. Ideal for quick diagnostic swapping |
Increased durability, ease of installation and high performance |
Can be installed on vessels governed by Class Society Rules |
SPECIFICATION
Power Supply | |
Input Supply Voltage | 9 to 35 V DC |
Input Supply Current | 325mA max @ 12V DC (all outputs @ full drive into 100 ohm loads) |
Input Protection | Continuous reverse polarity, transient overvoltage and ESD protection |
Power Indicator | LED, Blue – indicates unit is functioning correctly |
Input Supply Connector | Pluggable 2-way screw terminal, 5.08mm pitch |
NMEA 0183 Port – Listener & Talker | |
Number of Listener / Input Ports | 2 isolated NMEA 0183 Listeners |
Number of Talker / Output Ports | 12 isolated NMEA 0183 Talkers |
Compatibility | Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible |
Speed / baud rate | 4800 to 38400 bps |
Talker Output Voltage Drive | >= 2.2V (differential) into 100 ohm |
Talker Output Current Drive | 20 mA maximum per output |
Talker Output Protection | Short circuit and ESD |
Talker Data Indicator | LED, Orange (Flashes at data rate) |
Listener Input Voltage Tolerance | -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second) |
Listener Input Protection | Current limited, overdrive protection to 40 VDC and ESD protection |
Listener Data Indicator | LED, Green (Flashes to indicate valid input) |
Connectors | Pluggable 2/3-way screw terminals, 5.08mm pitch |
Serial Port | |
Compatibility | RS422 & RS232 compatible. RS485 Listener compatible |
Speed / baud rate | 4800 to 115200 bps |
Output Voltage Drive | >= 2.1V (differential) into 100 ohm |
Output Current Drive | 20 mA max. |
Output Protection | Short circuit and ESD |
Input Voltage Tolerance | -15 V to +15 V continuous, -35 V to +35 V short term (< 1 second) |
Input Protection | Current limited, overdrive protection to 40 VDC and ESD protection |
Data Indicators | LED’s: Green = Receive, Orange = Transmit |
Connectors | Pluggable 3-way screw terminals, 5.08mm pitch |
Ethernet Port | |
Host Interface | 10/100BaseT, automatic polarity detection |
Supported Protocols | TCP/IP for configuration and firmware updating |
TCP/IP and UDP for NMEA 0183 comms | |
Indicators | Green = Link/Activity, Yellow = 100 Mbps |
Connector | RJ45 |
Isolation | |
NMEA 0183 Listener | OPTO-Isolated, Hi-Pot tested to 1000V |
NMEA 0183 Talker | Uses IsoDriveTM, Hi-Pot tested to 1000V |
Serial Port | Uses IsoDriveTM, Hi-Pot tested to 1000V |
Alarm Relay | Hi-Pot tested to 1000V |
Ethernet Port | 2kV for 60s |
Mode Inputs | |
Input Voltage Range | 0 to 35V DC |
Protection | Transient overvoltage and ESD protection |
Connectors | Pluggable 2-way screw terminals, 5.08mm pitch |
Alarm Output | |
Contacts | Common, Normally Open and Normally Closed |
Alarm Indicator | LED, Red indicates a valid alarm condition |
Contact Ratings | 35VAC / 50VDC |
Connectors | Pluggable 3-way screw terminals, 5.08mm pitch |
Mechanical | |
Housing Material | 316 Stainless Steel |
Dimensions | 210mm (W) x 128mm (H) x 27mm (D) |
Weight | 530g |
Mounting | Bulkhead mount or DIN rail mount (DIN kit 1) |
Approvals and Certifications | |
EMC | IEC 60945:2002-08, DNVGL-CG-0339:2019 & IACS UR E10 Rev7 |
Compass Safe Distance | 750mm |
Type Approval Certificate | RINA |
Operating Temperature | -25 to +70°C |
Storage Temperature | -40 to +85°C |
Relative Humidity (RH) | 95% @ 55°C |
Environmental Protection | IP40 |
BOX